System 55T - 2 1/4" x 4 1/2" Thermal Framing


Marlin has combined excellent thermal performance with a truly versatile storefront/window wall framing system. Featuring a rigid polyurethane "thermal barrier" as an integral part of the extrusions.

System 55 has 2 1/4" x 4 1/2" framing members with glass to the front design. This system is typically glazed from the inside with 1" glazing. However it can be glazed from the outside and will accommodate 1/4" glazing for spandrel locations.

Ribbon or strip window utilize a 2 1/2" x 5" head/sill receptor. Vertical members slip into the receptors and head and sill inserts snap into the receptors to hold mullions in place.

Optional components allow for the integration of entrance doors and vestibule framing.

Stock Lengths/Parts & Pieces


Specifications

GENERAL

Aluminum framing shall be Marlin System 55 thermally improved as manufactured by Marlin Windows.

MATERIALS

All framing shall be aluminum extrusions of 6063-T5 alloy & temper with a minimum wall thickness of .094". All members shall have a rigid polyurethane "thermal barrier" as an integral part of the extrusion which eliminates all direct contact between the interior and exterior aluminum sections. Glazing gaskets shall be extruded E.P.D.M. System shall accommodate vertical structural silicone butt glazing.

FINISH

Standard architectural Class II anodic color conforming to Aluminum Association AA-M12-C22-A34 for dark bronze or AA-M12-C22-A31 for clear anodize. (Architectural Class I and Class II anodic finishes and organic coatings available).

CONSTRUCTION

Aluminum framing shall have a 2 1/4" face width and a depth of 4 1/2" and provide for flush glazing without projected stops. Head and sill members shall have a face dimension of 2 1/2" and a depth of 5". Optional thermally improved concealed project-in vent. Additional sight line shall not exceed 1/2"".

PERFORMANCE

System shall be tested in accordance with AAMA 501 and meet the requirements of ASTM E 283 for air infiltration, and ASTM E 331 for water penetration, and ASTM E 330 for structural performance. Deflection of mullions shall be limited to L/175 when subjected to the project design pressure of ____ P.S.F. (Architect to specify). Marlin System 55 shall have a minimum condensation resistance factor of 60.

GLAZING

Marlin system 55 shall accommodate 1" glazing as required. Provisions for 1/4" glazing shall be accommodated by use of an adapter.

INSTALLATION

Glass and framing shall be installed straight, plumb, and level without twisting and securely anchored in place. All joints between framing and the building exterior shall be sealed to provide a watertight installation.

PROTECTION AND CLEANING

The General Contractor shall provide adequate protection of the aluminum and glass surface from damage by grinding compound, lime, acids, cement or other contaminants. The General Contractor shall be responsible for final cleaning.