System 60 - Curtain
Wall
|
Marlin System
60 curtain wall combines the high
performance of pressure wall design with high span capabilities. By utilizing a
PVC thermal separator to eliminate direct contact between interior and exterior
aluminum sections, excellent thermal performance is also achieved.
System 60 framing members are 2 1/2" wide with an overall frame
depth of 5 3/4", 7 3/8", or 10". Steel reinforcing is available to
fit into the rectangular mullion when extra strength is required.
Horizontal members are attached to the vertical with shear anchor
clips.
Glass to the front design accepts 1" glazing with provisions
for 1/4" by use of an adaptor. Glass is held firmly in place by
screw applied pressure plates. Snap on cover plates leave a clean
exterior appearance.
System 60 offers optional components to accommodate entrance
doors, vestibule framing and interior partitions and various
exterior caps.
Stock Lengths/Parts & Pieces
|
 |
Specifications
GENERAL
Aluminum framing shall be Marlin System 60 thermally improved
as manufactured by Marlin Windows.
MATERIALS
All framing shall be aluminum extrusions of 6063-T5 alloy &
temper with a minimum wall thickness of .094". System 60 shall have
a PVC thermal separator to eliminate contact between the interior
and exterior aluminum sections. Glazing gaskets shall be extruded
E.P.D.M. System shall accommodate vertical structural silicone butt
glazing.
FINISH
Standard architectural Class II anodic color conforming to
Aluminum Association AA-M12-C22-A34 for dark bronze or
AA-M12-C22-A31 for clear anodize. (Architectural Class I and Class
II anodic finishes and organic coatings available).
CONSTRUCTION
Aluminum framing shall have a 2 1/2" face width and a depth of
5 3/4, 7 3/8" or 10" and provide for flush glazing without
projected stops.
SEISMIC
System shall be tested to withstand seismic racking without
loss of integrity.
PERFORMANCE
System 60 shall be tested in accordance with AAMA 501 and meet
the requirements of ASTM E 331 for water penetration, and ASTM E
330 for structural performance. Deflection of mullions shall be
limited to L/175 when subjected to the project design pressure of
____ P.S.F. (Architect to specify).
GLAZING
Marlin system 60 shall accommodate 1" glazing as required.
Provisions for 1/4" glazing shall be accommodated by use of an
adapter.
INSTALLATION
Experienced workman in accordance with approved shop drawings
shall install System 60. Glass and framing shall be installed
straight, plumb, and level without twisting and securely anchored
in place. All joints between framing and the building exterior
shall be sealed to provide a watertight installation.
PROTECTION AND CLEANING
The General Contractor shall provide adequate protection of the
aluminum and glass surface from damage by grinding compound, lime,
acids, cement or other contaminants. The General Contractor shall